Server IP : 85.214.239.14 / Your IP : 18.189.145.109 Web Server : Apache/2.4.62 (Debian) System : Linux h2886529.stratoserver.net 4.9.0 #1 SMP Tue Jan 9 19:45:01 MSK 2024 x86_64 User : www-data ( 33) PHP Version : 7.4.18 Disable Function : pcntl_alarm,pcntl_fork,pcntl_waitpid,pcntl_wait,pcntl_wifexited,pcntl_wifstopped,pcntl_wifsignaled,pcntl_wifcontinued,pcntl_wexitstatus,pcntl_wtermsig,pcntl_wstopsig,pcntl_signal,pcntl_signal_get_handler,pcntl_signal_dispatch,pcntl_get_last_error,pcntl_strerror,pcntl_sigprocmask,pcntl_sigwaitinfo,pcntl_sigtimedwait,pcntl_exec,pcntl_getpriority,pcntl_setpriority,pcntl_async_signals,pcntl_unshare, MySQL : OFF | cURL : OFF | WGET : ON | Perl : ON | Python : ON | Sudo : ON | Pkexec : OFF Directory : /srv/modoboa/env/lib64/python3.5/site-packages/gevent/ |
Upload File : |
""" Cooperative implementation of special cases of :func:`signal.signal`. This module is designed to work with libev's child watchers, as used by default in :func:`gevent.os.fork` Note that each ``SIGCHLD`` handler will be run in a new greenlet when the signal is delivered (just like :class:`gevent.hub.signal`) The implementations in this module are only monkey patched if :func:`gevent.os.waitpid` is being used (the default) and if :const:`signal.SIGCHLD` is available; see :func:`gevent.os.fork` for information on configuring this not to be the case for advanced uses. .. versionadded:: 1.1b4 """ from __future__ import absolute_import from gevent._util import _NONE as _INITIAL from gevent._util import copy_globals import signal as _signal __implements__ = [] __extensions__ = [] _child_handler = _INITIAL _signal_signal = _signal.signal _signal_getsignal = _signal.getsignal def getsignal(signalnum): """ Exactly the same as :func:`signal.getsignal` except where :const:`signal.SIGCHLD` is concerned. For :const:`signal.SIGCHLD`, this cooperates with :func:`signal` to provide consistent answers. """ if signalnum != _signal.SIGCHLD: return _signal_getsignal(signalnum) global _child_handler if _child_handler is _INITIAL: _child_handler = _signal_getsignal(_signal.SIGCHLD) return _child_handler def signal(signalnum, handler): """ Exactly the same as :func:`signal.signal` except where :const:`signal.SIGCHLD` is concerned. .. note:: A :const:`signal.SIGCHLD` handler installed with this function will only be triggered for children that are forked using :func:`gevent.os.fork` (:func:`gevent.os.fork_and_watch`); children forked before monkey patching, or otherwise by the raw :func:`os.fork`, will not trigger the handler installed by this function. (It's unlikely that a SIGCHLD handler installed with the builtin :func:`signal.signal` would be triggered either; libev typically overwrites such a handler at the C level. At the very least, it's full of race conditions.) .. note:: Use of ``SIG_IGN`` and ``SIG_DFL`` may also have race conditions with libev child watchers and the :mod:`gevent.subprocess` module. .. versionchanged:: 1.2a1 If ``SIG_IGN`` or ``SIG_DFL`` are used to ignore ``SIGCHLD``, a future use of ``gevent.subprocess`` and libev child watchers will once again work. However, on Python 2, use of ``os.popen`` will fail. .. versionchanged:: 1.1rc2 Allow using ``SIG_IGN`` and ``SIG_DFL`` to reset and ignore ``SIGCHLD``. However, this allows the possibility of a race condition if ``gevent.subprocess`` had already been used. """ if signalnum != _signal.SIGCHLD: return _signal_signal(signalnum, handler) # TODO: raise value error if not called from the main # greenlet, just like threads if handler != _signal.SIG_IGN and handler != _signal.SIG_DFL and not callable(handler): # exact same error message raised by the stdlib raise TypeError("signal handler must be signal.SIG_IGN, signal.SIG_DFL, or a callable object") old_handler = getsignal(signalnum) global _child_handler _child_handler = handler if handler in (_signal.SIG_IGN, _signal.SIG_DFL): # Allow resetting/ignoring this signal at the process level. # Note that this conflicts with gevent.subprocess and other users # of child watchers, until the next time gevent.subprocess/loop.install_sigchld() # is called. from gevent.hub import get_hub # Are we always safe to import here? _signal_signal(signalnum, handler) get_hub().loop.reset_sigchld() return old_handler def _on_child_hook(): # This is called in the hub greenlet. To let the function # do more useful work, like use blocking functions, # we run it in a new greenlet; see gevent.hub.signal if callable(_child_handler): # None is a valid value for the frame argument from gevent import Greenlet greenlet = Greenlet(_child_handler, _signal.SIGCHLD, None) greenlet.switch() import gevent.os if 'waitpid' in gevent.os.__implements__ and hasattr(_signal, 'SIGCHLD'): # Tightly coupled here to gevent.os and its waitpid implementation; only use these # if necessary. gevent.os._on_child_hook = _on_child_hook __implements__.append("signal") __implements__.append("getsignal") else: # XXX: This breaks test__all__ on windows __extensions__.append("signal") __extensions__.append("getsignal") __imports__ = copy_globals(_signal, globals(), names_to_ignore=__implements__ + __extensions__, dunder_names_to_keep=()) __all__ = __implements__ + __extensions__