Dre4m Shell
Server IP : 85.214.239.14  /  Your IP : 18.216.92.5
Web Server : Apache/2.4.62 (Debian)
System : Linux h2886529.stratoserver.net 4.9.0 #1 SMP Tue Jan 9 19:45:01 MSK 2024 x86_64
User : www-data ( 33)
PHP Version : 7.4.18
Disable Function : pcntl_alarm,pcntl_fork,pcntl_waitpid,pcntl_wait,pcntl_wifexited,pcntl_wifstopped,pcntl_wifsignaled,pcntl_wifcontinued,pcntl_wexitstatus,pcntl_wtermsig,pcntl_wstopsig,pcntl_signal,pcntl_signal_get_handler,pcntl_signal_dispatch,pcntl_get_last_error,pcntl_strerror,pcntl_sigprocmask,pcntl_sigwaitinfo,pcntl_sigtimedwait,pcntl_exec,pcntl_getpriority,pcntl_setpriority,pcntl_async_signals,pcntl_unshare,
MySQL : OFF  |  cURL : OFF  |  WGET : ON  |  Perl : ON  |  Python : ON  |  Sudo : ON  |  Pkexec : OFF
Directory :  /proc/2/cwd/proc/2/root/proc/2/cwd/proc/3/root/proc/2/cwd/usr/share/snmp/mibs/

Upload File :
current_dir [ Writeable ] document_root [ Writeable ]

 

Command :


[ HOME SHELL ]     

Current File : /proc/2/cwd/proc/2/root/proc/2/cwd/proc/3/root/proc/2/cwd/usr/share/snmp/mibs/LM-SENSORS-MIB.txt
LM-SENSORS-MIB DEFINITIONS ::= BEGIN

--
-- Derived from the original VEST-INTERNETT-MIB. Open issues:
--
-- (a) where to register this MIB?
-- (b) use not-accessible for diskIOIndex?
--


IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32
        FROM SNMPv2-SMI
    DisplayString
        FROM SNMPv2-TC
    ucdExperimental
        FROM UCD-SNMP-MIB;

lmSensorsMIB MODULE-IDENTITY
    LAST-UPDATED "200011050000Z"
    ORGANIZATION "AdamsNames Ltd"
    CONTACT-INFO    
        "Primary Contact: M J Oldfield
         email:     m@mail.tc"
    DESCRIPTION
        "This MIB module defines objects for lm_sensor derived data."
    REVISION     "200011050000Z"
    DESCRIPTION
        "Derived from DISKIO-MIB ex UCD."
    ::= { lmSensors 1 }

lmSensors      OBJECT IDENTIFIER ::= { ucdExperimental 16 }

--

lmTempSensorsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF LMTempSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of temperature sensors and their values."
    ::= { lmSensors 2 }

lmTempSensorsEntry OBJECT-TYPE
    SYNTAX      LMTempSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry containing a device and its statistics."
    INDEX       { lmTempSensorsIndex }
    ::= { lmTempSensorsTable 1 }

LMTempSensorsEntry ::= SEQUENCE {
    lmTempSensorsIndex    Integer32,
    lmTempSensorsDevice   DisplayString,
    lmTempSensorsValue    Gauge32
}

lmTempSensorsIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reference index for each observed device."
    ::= { lmTempSensorsEntry 1 }

lmTempSensorsDevice OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the temperature sensor we are reading."
    ::= { lmTempSensorsEntry 2 }

lmTempSensorsValue OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The temperature of this sensor in mC."
    ::= { lmTempSensorsEntry 3 }
--

lmFanSensorsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF LMFanSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of fan sensors and their values."
    ::= { lmSensors 3 }

lmFanSensorsEntry OBJECT-TYPE
    SYNTAX      LMFanSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry containing a device and its statistics."
    INDEX       { lmFanSensorsIndex }
    ::= { lmFanSensorsTable 1 }

LMFanSensorsEntry ::= SEQUENCE {
    lmFanSensorsIndex    Integer32,
    lmFanSensorsDevice   DisplayString,
    lmFanSensorsValue    Gauge32
}

lmFanSensorsIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reference index for each observed device."
    ::= { lmFanSensorsEntry 1 }

lmFanSensorsDevice OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the fan sensor we are reading."
    ::= { lmFanSensorsEntry 2 }

lmFanSensorsValue OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The rotation speed of the fan in RPM."
    ::= { lmFanSensorsEntry 3 }

--

lmVoltSensorsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF LMVoltSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of voltage sensors and their values."
    ::= { lmSensors 4 }

lmVoltSensorsEntry OBJECT-TYPE
    SYNTAX      LMVoltSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry containing a device and its statistics."
    INDEX       { lmVoltSensorsIndex }
    ::= { lmVoltSensorsTable 1 }

LMVoltSensorsEntry ::= SEQUENCE {
    lmVoltSensorsIndex    Integer32,
    lmVoltSensorsDevice   DisplayString,
    lmVoltSensorsValue    Gauge32
}

lmVoltSensorsIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reference index for each observed device."
    ::= { lmVoltSensorsEntry 1 }

lmVoltSensorsDevice OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the device we are reading."
    ::= { lmVoltSensorsEntry 2 }

lmVoltSensorsValue OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The voltage in mV."
    ::= { lmVoltSensorsEntry 3 }

--

lmMiscSensorsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF LMMiscSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of miscellaneous sensor devices and their values."
    ::= { lmSensors 5 }

lmMiscSensorsEntry OBJECT-TYPE
    SYNTAX      LMMiscSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry containing a device and its statistics."
    INDEX       { lmMiscSensorsIndex }
    ::= { lmMiscSensorsTable 1 }

LMMiscSensorsEntry ::= SEQUENCE {
    lmMiscSensorsIndex    Integer32,
    lmMiscSensorsDevice   DisplayString,
    lmMiscSensorsValue    Gauge32
}

lmMiscSensorsIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reference index for each observed device."
    ::= { lmMiscSensorsEntry 1 }

lmMiscSensorsDevice OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the device we are reading."
    ::= { lmMiscSensorsEntry 2 }

lmMiscSensorsValue OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of this sensor."
    ::= { lmMiscSensorsEntry 3 }


END

Anon7 - 2022
AnonSec Team